Cleaning Surgical Instruments Cleaner remove stains Enzymatic enzyme detergent for cleaning surgical instruments cleaner surgical instrument cleaning.
Cleaning Surgical Instruments Cleaner remove stains Enzymatic enzyme detergent for cleaning surgical instruments cleaner surgical instrument cleaning.
Enzyme Detergent Lubricant for cleaning Surgical Instruments. 
The Surgical Instrument Cleaner with Conditioning for cleaning Surgical Instruments cleaner, with lower cleaning costs.
ONE gallon of the all-in-ONE the Surgical Instrument Cleaner will deliver 512 gallons of fast acting and cost effective Surgical Instrument Cleaners and Conditioners.
Buy one surgical instrument detergent enzyme cleaner product for cleaning surgical instruments cleaner.
Buy Surgical Instrument Detergents that will cut costs, guaranteed.

Customer Service: 1-800-341-7048
CustomerService@ergo-Logistics.com
Buy Surgical Instrument Detergents that will cut costs, guaranteed. Buy Surgical Instrument Detergents that will remove stains.
Buy Surgical Instrument Detergents for cleaning surgical instruments cleaner.
Contact us for product information and pricing. The all-in-ONE Surgical Instrument Cleaner will lower your cleaning and conditioning costs and replace multiple Surgical Instrument Care products for cleaning Surgical Instruments and cleaning Endoscopes.
Importance of Cleaning Surgical Instruments
The primary purpose of cleaning surgical instruments is to remove all inorganic and organic proteinaceous bioburden material from the internal and external surfaces cleaning surgical instruments inside and out with careful attention to cleaning cannulated surgical instruments. The secondary purpose of cleaning surgical instruments is to maintain and improve the passive Layer of surgical stainless steel. The passive layer is provided by the manufacturer of the surgical instruments, within the surgical stainless steel, to resist (prevent) corrosion. Proper cleaning of the surgical instrument will maintain and improve this passive layer. (for more information go to: Prevent Corrosion ) If the manual cleaning, brushing and rinsing steps are not properly carried out, protein debris can harden and lead to formation of biofilm on the surgical instrument, i.e. the biopsy channel of an endoscope. The optimal surgical instrument cleaning protocol will break down proteinaceous bioburden and clean the surface. Inadequate cleaning can result in material remaining on the surgical instrument which will prevent disinfection and sterilization fluids or gases reaching all parts of the potentially contaminated device. Inadequate sterilization or disinfection sterilization and may in turn result in transmission of infectious organisms when the device is reused. The intricate design and delicate materials of flexible scopes complicate the cleaning process. This requires repetitive and consistent oversight.
The all-in-ONE Surgical Instrument cleaner will lower surgical instrument cleaning costs.
The easy FOAM-it Surgical Instrument cleaner will clean surgical instruments fast.
Surgical Instrument Cleaning Detergent: Enzyme Detergent Lubricant.
Cleaning Surgical Instruments is the Prerequisite for Sterilization
The reprocessing decontamination Cleaning of Surgical Instruments, whether done manually or automatically in a surgical instrument washer decontaminator disinfector, can only be effective if "cleaning" is adequate. Effectively sterilizing surgical instruments (Generic Sterilization with a Pre-Vacuum Sterilizer (HI-VAC): 270-272° F (132-134° C), 16-minute exposure time, with 4 pulses and a  30-minute dry time. Generic Sterilization with a Gravity Displacement Sterilizer: 270-272° F (132-134° C), 30-minute exposure time, with a 30-minute dry time.) is not possible if "cleaning", the "prerequisite for sterilizing surgical instruments", is not adequate. All disinfection processes, whether done manually or done automatically in a surgical instrument washer decontaminator disinfector, can only be effective if prior cleaning is adequate. Effective disinfection or sterilization of an inadequately cleaned surgical instrument or scope is not possible. Endoscopes should be cleaned with an enzymatic enzyme detergent compatible with the endoscope immediately after use and before manual or automated disinfection. Cleaning involves the entire endoscope, including valves, working channels, connectors and all detachable parts. High level enzymatic enzyme detergent formulations Enzymatic Surgical Instrument Cleaners), in combination with a high level surfactant chemical complex, have been shown to be effective in removing stains, hard water deposits, and encrusted bioburden, while being safe to use for rigid or flexible scopes.
The all-in-ONE Enzymatic enzyme detergents
Surgical Instrument Cleaner replaces multiple products:
  • enzymatic cleaners,
  • surgical instruments cleaning chemicals,
  • stain removers for surgical instruments,
  • surgical instrument passive layer surface conditioners,
  • and lubricants for surgical instruments.
Cleaning Surgical Instruments cleaner.
The all-in-ONE Enzymatic enzyme detergents
Surgical Instrument Cleaner is for multiple applications:
  • manually cleaning surgical instruments,
Contact us for product information and pricing.
Enzymatic enzyme detergents
all-in-ONE Surgical Instrument Cleaner easy FOAM-it - 12 per case
all-in-ONE Surgical Instrument Cleaner - 4 gallons per case
all-in-ONE Surgical Instrument Cleaner - 5 gallon
all-in-ONE Surgical Instrument Cleaner - 15 gallon
all-in-ONE Surgical Instrument Cleaner - 30 gallon
all-in-ONE Surgical Instrument Cleaner - 55 gallon
Buy Surgical Instrument Detergents that will cut costs, guaranteed. Buy Surgical Instrument Detergents that will remove stains.
Buy Surgical Instrument Detergents for cleaning surgical instruments cleaner.
Enzyme Surgical Instrument Cleaning Enzymes: Enzymes are costly, clinically and financially effective. 
Manufacturers of surgical instrument usually recommend that Enzyme Cleaning concentrates should be discarded after each use as these products are not microbicidal and will not retard microbial growth. Some manufactures of "combination" or all-in-one surgical instrument cleaning concentrates include a bacteriostatic agent which will prevent the growth of microorganisms. Some detergent complexes contain antimicrobial-microbicidal substances. Although these agents do not replace disinfection they are designed to reduce the risk of infection to reprocessing personnel by rendering instruments that are clean and safe to handle. The cleaning function efficacy of enzyme cleaning concentrates is determined by the ratio of enzymes to bioburden. The higher the proportion of enzymes the higher the efficacy. As a result, if the cleaning solution becomes laden with bioburden from previous cleaning, the efficacy of the enzyme cleaning concentrates is lower. When a cleaning concentrate states that is it "multi-tiered", the inference is that is contains: protease (enzyme) which break protein debris into smaller, more soluble subunits, amylase (enzyme) which catalyses the breakdown of starch, and lipase (enzyme) which breaks up fat-containing debris and carbohydrates. When a detergent cleaning concentrate states that is it "high-level", the inference is that is contains a high concentration of enzymes. When a cleaning concentrate states that is provides "enzyme activity" the inference is that is contains enzymes but this is usually is a misrepresentation of ingredients for a detergent cleaning concentrate that does not contain enzymes. Enzymes are effective and they are costly for manufacturers to include in the formulation. As is true for all detergent cleaning concentrates, the most effective test is against your most difficult cleaning challenge. The two most common tests for cleaning concentration efficacy that are commercially available are the "TOSI Test" and the "film test". Be aware that some manufacturers use advertising wordage and product names that imply enzymes are an active ingredient but do not actually include enzymes in their product formulation. Refer to product labels and ingredients for disclosure.
Optimal Temperature for Cleaning Surgical Instruments
Ultrasonic Cleaner Solution
Enzyme Cleaning Concentrates
Enzyme cleaning concentrates function more effectively at temperatures above room temperature. The optimal range begins as > 22C - 72°F with performance reaching it's peak at 58.3C - 137F. This is often referred to as the optimal temperature for the performance or activity of enzymatic action. The activity of enzymes does not stop at higher temperatures but the level of performance does begin to decrease. Enzyme cleaning concentrates enzyme-detergents and all-in-one cleaning concentrates, which include enzymes, should be used in accordance with the manufacturer's recommendations and the recommendations of the medical devices being cleaned.
Cleaning Surgical Instruments in the presence of pathological prions
(Creutzfeld-Jakob disease) deactivating prions (protein and prion contamination)
The approach for cleaning surgical instruments can be the same if the presence of pathological prions (including the prions of vCJD Creutzfeld-Jakob disease) however the attention to detail is more important. It is known, that prions are unusually resistant to disinfection and sterilization by the physical and chemical methods used for decontamination of infectious pathogens. It is a difficult task to gain a consensus opinion on what constitutes optimal and practical conditions for decontamination of prions. Numerous studies have been conducted, but they do not reflect the reprocessing procedures for surgical instruments in a clinical setting. The clinical setting is critical for iatrogenic transmission, the passing of a disease from an infected individual or group to a previously uninfected individual or group. The method of reprocessing prion contaminated surgical instruments includes (1) decontamination by NaOH or NaOCl for 30 or 60 minutes followed by GL-autoclaving at 121°C for 30 minutes, (2) cleaning and (3) routine PL-sterilizing at 134°C. It is known that some surgical instruments cannot be decontaminated by heat and moisture. Disinfectants have been widely used for this purpose even although the disinfectants are ineffective. The most common practice believes that the only completely safe way to prevent transmission of vCJD is to use single-use surgical instruments. Because of the pervasive distribution of these infectious proteins and the long incubation time of the disease, reprocessing cleaning surgical instruments has been identified as a high risk factor for nosocomial transmission of vCJD. Research has shown that the agent of the vCJD disease, an infectious prion protein, is extremely resistant to today’s sterilization methods; therefore, the argument, “It does not matter if instruments are 100 percent clean, as they will be sterilized,” is definitely no longer valid. Today, we understand that cleaning surgical instruments is as important as the sterilizing the surgical instruments. Today’s surgical instrument cleaning process requires increasingly sophisticated surgical instrument cleaning concentrates. Detergents, which are used in these processes, can be mild, with a neutral pH, or they may be more aggressive, with values in the alkaline range of the pH scale. A number of hospitals and surgical centers are effectively using neutral pH “combination” enzymatic enzyme detergent cleaners for reprocessing surgical instruments. The “combination” enzyme detergent cleaners provide optimal cleaning as well as the highest possible level of care for surgical instruments and scopes. The manufacturers of surgical instruments strongly recommend the use of Neutral pH cleaners to enhance the "passive layer" of instrument protection. The early prion inactivation approach, using a high concentrate of sodium hydroxide solution or sodium hypochlorite combined with long holding times, is generally lethal for medical surgical instruments and washer-decontaminators- disinfectors. Recently, researchers have been looking is a minimally destructive method to decontaminate surgical instruments potentially contaminated with prions. The use of “combination” enzyme detergent surgical instrument cleaners has offered the highest level of cleaning outcomes.
Buy Surgical Instrument Detergents that will cut costs, guaranteed. Buy Surgical Instrument Detergents that will remove stains.
Buy Surgical Instrument Detergents for cleaning surgical instruments cleaner.
Ultrasonic Cleaner Solution - Cleaning Surgical Instruments
Ultrasonic cleaning of reusable endoscope accessories and components may be needed to remove material from hard-to-clean areas. The same detergent used for ultrasonic cleaning can be the same as used for manual cleaning. Recommendations for detergents used for ultrasonic cleaning are as follows:
a non-foaming detergent must used, the labeling of the detergent should recommend the use of the product for ultrasonic cleaning, always use enzymatic detergents for instruments soiled with bioburden (protein, fats, starch), use detergents with 'surfactant' cleaning agents for removing stains and hard water mineral deposits,  the treatment cleaning time recommended by the medical device and detergent manufacturers should be observed, avoid the inhalation of enzyme-containing detergent aerosols (risk of anaphylactic reactions) by maintaining a cover over the ultrasonic cleaner when in use.
Ultrasonic Cleaner Solution
Cleaning Surgical Instruments and Cleaning Endoscopes
Ultrasonic cleaners are very effective when used with hot water per manufacturer’s recommended temperature and specially formulated detergents. It is recommended that all visible debris and blood be removed from the instrument prior to ultrasonic cleaning.  Sort instruments by similar metals to prevent corrosion due to the contact of dissimilar metals. (electrolytic deposition - galvanic corrosion) It is not recommended to clean plated instruments in an ultrasonic cleaner since the ultrasonic vibration and the presence of other sharp instruments may crack or rupture the plating. Because Ultrasonic Cleaners do not provide the complete "proper sequence of treatments" i.e. final rinse(s) that are purified, purged between treatments, and/or have temperatures elevated to disinfection levels, they are not considered to be as clinically effective as automated washer-decontaminators- disinfectors. Ultrasonic Cleaning can effectively remove: long term encrustation and surgical cements or glues that have dried onto instrumentation. Always refer to the printed manufacturer recommendations prior to using Ultrasonics. Recommendations for Maximizing the Efficacy of Ultrasonic Cleaning: items being cleaned must be fully immersed, hinged instruments must remain open during treatment, only use cleaning trays that do not obstruct the ultrasonic cleaning process or add mass (e.g. wire baskets), arge surface bulky items such as kidney shaped bowls must be positioned not to create anechoic (shadow) zones that will block the efficacy of ultrasonic transducer waveform. Position such items vertically or put them on top of the other items.
Recommendations for Maximizing the Efficacy of Ultrasonic Cleaning: always sort instruments by similar metals to prevent corrosion, do not overload the ultrasonic cleaning tank with excessive mass as this will reduce the efficacy of cleaning, the soil being removed from devices being cleaned adds to the mass within the tank and decreases the efficacy of the ultrasonic cleaner. Review the level of soil and renew the ultrasonic bath as needed. Follow ultrasonic cleaning with separate rinse treatments. Ultrasonic cleaning will fragment and loosen soil but will not necessarily remove the soil from the surface of the surgery instrument being cleaned.

Cleaning Surgical Instruments 
Cleaning Concentrates - Detergents
for Cleaning Surgical Instruments Ultrasonic Cleaner Solution
For the cleaning of endoscopes, detergents with or without enzymes, and detergents containing antimicrobial substances may be used. Use of non-foaming detergents is recommended. Foaming can inhibit good fluid contact with device surfaces, and prevent a clear field of vision during the cleaning process with a risk of injury to personnel.
The detergent selected should effectively loosen organic and non-organic material so that the flushing action of the detergent fluid and subsequent rinsing water removes the unwanted material. Combination all-in-one Enzymatic Surgical Instrument Cleaner detergent complexes have been shown to be highly effective.
Aldehydes Contained in Cleaning Concentrates
for Cleaning Surgical Instruments Ultrasonic Cleaner Solution
When using Cleaning Concentrates which contain Aldehydes, be aware that they denature and coagulate protein.
Amine Compounds or Glucoprotamine in combination with Glutaraldehyde and Cleaning Concentrates
Detergents based on amine compounds or glucoprotamine in combination with glutaraldehyde for disinfection should not be used as chemical reactions may result in formation of colored residues. These residues can appear to be corrosion. The use of a high level cleaning surfactant "combination" enzyme detergent instrument cleaner can be used to remove the corrosion-stains, and prevent corrosion or stains.

John Temple
Product Development

Cleaning Surgical Instruments  
Clean is Safe 
Risk Cleaning Surgical Instruments
Summary:  It is a recognized risk of exposure to unidentified microorganisms that processing personal endure during the reprocessing of surgical instruments. Our goal is to minimize the amount and degree of processing personal exposure to this risk and provide processed surgical instruments that are clean: safe to handle, safe for patient care, are processed at the lowest cost, and have received the prerequisite for disinfecting surgical instruments and/or sterilizing surgical instruments.

Typically, hospitals hand wash surgical instruments: with dried on or excessive debris, that incorporate working channels and/or lumens, or when automated washing is not available.  Hand washing places the processing personnel at risk. In the decontamination area, surgical instruments are received that are contaminated with variable amounts of debris and unidentified microorganisms. In the clean side processing area, devices requiring further processing are handled by unprotected personnel.  

Cleaning Surgical Instruments
Workers at Risk Cleaning Surgical Instruments
Inherent in the manual decontamination process is power spraying, splashing, the creation of the contaminated aerosols and the potential for infectious punctured wounds. The handling of each individual device is time consuming, labor intensive, renders limited through-put and has high overhead costs.

Exposure Contained by Automated Washer Decontaminator Cleaning Surgical Instruments

An automated washer decontaminator can, and should, safely contain within its chambers the washing action, removal of debris and contaminated aerosols.  The batch treatment of devices by Washer Decontaminators saves time, increases material through-put, provides for FTE reduction and lower component cost. It has been demonstrated that a properly designed Washer Decontaminator, that is used to manufacturer’s specifications, will consistently and repeatedly remove all microorganisms. 
Washer Decontaminators should be used in accordance with the manufacturer’s direction for use, to secure the most consistent and efficacious results.  Worker safety or processing efficacy can be compromised by violating the manufacturer’s recommendations.  Examples of such recommendations are: Keeping working chambers closed during processing and the use of purified water final rinses. 
Surgical Instrument Cleaner with Conditioners for cleaning Surgical Instruments cleaner.    
A Clean Surgical Instrument is Safe to Handle
It is critical that devices are cleaned properly to secure the safety of workers in the clean area.  During the steps of inspection, sorting and packaging of devices, the unprotected processing personnel are repeatedly at risk from a surgical instrument that has remained contaminated with microorganisms. 
Within the implementation of the Universal Decontamination Precautions, it is our goal to eliminate exposure or reduce risk whenever possible.

The use of proper hand washing decontamination methods can render surgical instruments that are clean, but requires continual worker exposure to contaminated devises.  The workers performance is influenced by skill level, knowledge and work load.  This may impact the efficacy of the process. The use of a properly designed washer decontaminator eliminates and reduces overhead cost and provides consistence removal of all microorganisms.  Once a surgical instrument is clean, it is then safe for further processing and handling. Proper cleaning is the prerequisite for disinfecting and/or sterilizing surgical instruments. Optimal cleaning can render surgical instruments that, at the end of the cleaning process, are sterile.
Buy Surgical Instrument Detergents that will cut costs, guaranteed. Buy Surgical Instrument Detergents that will remove stains.
Buy Surgical Instrument Detergents for cleaning surgical instruments cleaner.

John Temple
Product Development

The all-in-ONE Neutral pH Surgical Instrument Cleaners will replace multiple Surgical Instrument Care products:
  • enzyme surgical instrument cleaners,
  • surgical instrument cleaning chemicals,
  • stain removers for surgical instruments,
  • surgical instrument "passive layer" surface conditioners,
  • and surgical instrument lubricants.

The all-in-ONE Surgical Instrument Cleaners will replace multiple Surgical Instrument Care products:
  • manually cleaning surgical instruments,
  • automated surgical instrument washer decontaminators,
  • surgical instrument washer disinfectors,
  • ultrasonic surgical instrument cleaners,
  • and scope cleaners.

Surgical Instrument Cleaner with Conditioners for cleaning Surgical Instruments cleaner. 

Cleaning Surgical Instruments Cleaner remove stains Enzymatic enzyme detergent for cleaning surgical instruments cleaner surgical instrument cleaning.
Cleaning Surgical Instruments Cleaner remove stains Enzymatic enzyme detergent for cleaning surgical instruments cleaner surgical instrument cleaning.
Cleaning Surgical Instruments Cleaner remove stains Enzymatic enzyme detergent for cleaning surgical instruments cleaner surgical instrument cleaning.
Cleaning Surgical Instruments Cleaner remove stains Enzymatic enzyme detergent for cleaning surgical instruments cleaner surgical instrument cleaning.
ONE Enzyme Detergent product for
Surgical Instrument Cleaning and Conditioning.
ONE Enzyme Detergent application for
Surgical Instrument Cleaning and Conditioning fast and cost effectively.
Apply it ONCE. It's all you really need for cleaning Surgical Instruments cleaner.
Contact us today for high quality instrument cleaning with lower cleaning costs.
The Enzyme Detergent Surgical Instrument Lubricant
all-in-ONE Surgical Instrument Detergent Cleaner easy FOAM-it© - 12 per case
all-in-ONE Surgical Instrument Cleaner - 4 gallons per case
all-in-ONE Surgical Instrument Cleaner - 5 gallon
all-in-ONE Surgical Instrument Cleaner - 15 gallon
all-in-ONE Surgical Instrument Cleaner - 30 gallon
all-in-ONE Surgical Instrument Cleaner - 55 gallon
The Dilution rate is .25 to .5 ounces per gallon depending on level of bioburden, encrustation and stains.
Contact us today for high quality instrument cleaning with lower cleaning costs.
ONE product for Surgical Instrument Cleaning and Conditioning.
ONE application for cleaning Surgical Instruments cleaner